checking ups fault

5 Common Causes of UPS Failure

UPS failure can result from many factors. When this happens, there is unfortunately no shortage of potential mishaps.

Whether you are operating aging infrastructure or looking to optimize the lifespan of newer equipment, consider some of the most common UPS components that are susceptible to failure:

1. Batteries. As the heart of any UPS system, batteries require a constant check-up to ensure they remain fit to safeguard critical systems. Regardless of their age, batteries should be inspected semi-annually as part of a PM visit that includes testing for impedance or conductance, as well as assesses performance and evaluates any potential weaknesses.

2. Capacitors. A fairly simple device that stores and releases electrical energy, capacitors range in size and type, and generally need to be replaced every 5 to 7 years. A typical UPS contains a dozen or more capacitors, which are responsible for smoothing out and filtering voltage fluctuations. However, because capacitors degrade over time, annual inspection helps to optimize their operation and extend their lifespan.

3. Fans. Some UPS fans may perform well for 10 years of continuous use, while others could run for just a short time before locking up or failing. Electrical or mechanical limitations and dried-out ball bearings are common issues that can result in fan failures and subsequent UPS overheating.

4. Filters. UPS are also prone to overheating (and shutting down) when dust or other coatings block air filters. Because replacing filters is an inexpensive component of an effective UPS maintenance plan, they should be inspected on a monthly basis and changed as needed.

5. Connections. An annual PM visit gives a trained service technician the opportunity to inspect the UPS and battery cabinets for loose internal connections, which can result from machinery situated close to the unit or from building vibrations.

While it’s clear that UPS components are prone to failure for a variety of reasons, investing in preventive maintenance with a professional and skilled service provider will appreciably reduce your risk of downtime — and potential disaster.

At Actolog Solutions, we are committed to delivering exceptional, timely maintenance performed by highly trained industry professionals.

May be an image of text that says 'PREVENTIVE MAINTENANCE + 000 ACTOLOG ACTOLOG SOLUTIONS ....adding value,redefining ervice'

We sell and install the best brand of UPS, Stabilizers, and Inverters. We provide solutions to power/energy challenges
Posts created 36

6 thoughts on “5 Common Causes of UPS Failure

  1. Thank you, I’ve recently been looking for information about this topic for ages and yours is the greatest I’ve discovered so far. But, what about the conclusion? Are you sure about the source?

  2. I precisely had to say thanks yet again. I do not know what I could possibly have taken care of in the absence of those smart ideas contributed by you directly on that subject matter. Previously it was the intimidating matter for me, but witnessing this specialised tactic you managed the issue took me to jump over gladness. I am happy for the advice as well as pray you comprehend what an amazing job you are always putting in teaching the rest via your web page. I know that you’ve never come across any of us.

  3. I抎 should check with you here. Which isn’t something I often do! I enjoy studying a post that may make people think. Additionally, thanks for permitting me to comment!

Leave a Reply

Your email address will not be published. Required fields are marked *